User guide

Rockwell Automation Publication 2094-UM003A-EN-P - May 2012 103
Appendix A
Using the Safe Torque-off Feature with the
Kinetix 6000M System
This appendix introduces you to how the safe torque-off feature meets the
requirements of Performance Level d (PLd) and Category 3 (Cat3) per EN ISO
13849-1 and SIL CL 2 per IEC EN 61508, EN 61800-5-2 and EN 62061.
Certification
The TÜV Rheinland group has approved the Kinetix 6000M integrated drive-
motor system for use in safety-related applications up to EN ISO 13849-1
performance level d (PLd) and category 3, SIL CL 2 per IEC EN 61508, EN
61800-5-2 and EN 62061, in which removing the motion producing power is
considered to be the safe state.
Important Safety Considerations
The system user is responsible for the following:
Validation of any sensors or actuators connected to the system
Completing a machine-level risk assessment
Certification of the machine to the desired EN ISO 13849-1 performance
level or EN 62061 SIL level
Project management and proof testing
Topic Page
Certification 103
Description of Operation 104
PFD, PFH, and MTTFd Definitions 107
PFD, PFH, and MTTFd Data 107
Wiring Your Safe Torque-off Circuit 107
IDM Safe Torque-off Feature 108
IDM System Safe Torque-off Example 109
Cascading the Safe Torque-off Signal 110
Safe Torque-off Signal Specifications 111