Owner manual
B-6 PROFIBUS Communications Module
Sets the corresponding node addresses of the daisy-chained drives
when the module Mode Jumper (J2) is set for Multi-Drive operation.
Important: The settings for these parameters must match the
Comm Node Addr (parameter A104) settings in the
respective drives. Each setting must also be unique (no
duplicate node address).
Displays the state of the PROFIBUS controller.
17
18
19
20
21
Drv 0 Addr
Drv 1 Addr
Drv 2 Addr
Drv 3 Addr
Drv 4 Addr
Range: 1 - 125
Default: Drv 0 Addr = 1
Drv 1 Addr = 2
Drv 2 Addr = 3
Drv 3 Addr = 4
Drv 4 Addr = 5
Type: Read/Write
Reset Required: Ye s
24 P-DP State
Range: 0 = WAIT_PRM
1 = WAIT_CFG
2 = DATA_EX
3 = ERROR
Default: N/A
Type: Read Only
Reset Required: N/A