Quick Start Manual

18 Rockwell Automation Publication IASIMP-QS035A-EN-P - December 2012
Chapter 1 Prepare the Kinetix 5500 Drive Hardware
Wire Drive Connectors
Kinetix 5500 servo drives are capable of 200V-class (single/three-phase) and 400V-class (three-phase) operation.
This wiring diagram is for 200/400V-class, three-phase operation. For additional interconnect wiring diagrams,
refer to the Kinetix 5500 Servo Drives User Manual, publication 2198-UM001.
Interconnect Wiring Diagram
Interconnect Diagram Notes
Note Information
1 AC (EMC) line filter is required for EMC compliance. Place line filter as close to the drive as possible and do not route very dirty wires in wireway. If routing in wireway is
unavoidable, use shielded cable with shields grounded to the drive chassis and filter case. For AC line filter specifications, refer to Kinetix Servo Drives Specifications Technical
Data, publication GMC-TD003
.
2 Terminal block is required to make connections.
3 Cable shield clamp must be used to meet CE requirements.
4 PE ground connection bonded to the panel must be used to meet CE requirements.
5 DC connector covered with protective knockout is default configuration. Wiring the DC connector does not apply to standalone drives.
6 Internal shunt wired to the RC connector is default configuration. Remove internal shunt wires to attach external shunt wires.
7 Default configuration for ground screws is for grounded power at user site. For ungrounded or corner-grounded power, remove the screws. Refer to Ground the Kinetix 5500
Drive on page 17
for more information.
DATA +/EPWR+
DATA -/EPWR-
L3
L2
L1
24V_COM
+24V
2
1
MBRK -
MBRK +
DC+
DC-
D+
D-
IN1
COM
IN2
SHLD
1
2
4
3
2
1
1
2
3
4
MBRK -
MBRK +
U
V
W
2
1
4
3
2
1
DC+
SH