Owner's manual
Table Of Contents
- Front Cover
- Important User Information
- Summary of Changes
- Table of Contents
- Introduction
- About the Drive
- Identifying the Drive by Cabinet Assembly ID Number
- LiquiFlo 2.0 Drive Component Locations
- Identifying the Power Module by Model Number
- AC Line I/O Board Description (Frame 3 Only)
- Standard I/O Board Description (Frame 3 Only)
- Combined I/O Board Description (Frame 4 Only)
- DPI Communication Ports
- Optional Equipment
- Planning the Installation
- Mounting The Power Module and Grounding the Drive
- Installing Input and Output Power Wiring
- Completing the Installation
- Using the Start-up Routines
- Programming Basics
- Parameter Descriptions
- Troubleshooting the Drive
- Verify that the DC Bus Capacitors are Discharged Before Servicing the Drive
- Determining Drive Status Using the Status LEDs
- About Alarms
- About Faults
- Diagnostic Parameters
- Common Symptoms and Corrective Actions
- Replacement Parts
- Board Replacement, Firmware Setup Procedures
- Troubleshooting the Drive Using the OIM
- Checking the Power Modules with Input Power Off
- Technical Specifications
- Using the OIM
- Installing and Removing the OIM
- Display Description
- OIM Menu Structure
- Powering Up and Adjusting the OIM
- Selecting a Device in the System
- Using the OIM to Program the Drive
- Monitoring the Drive Using the Process Display Screen on the OIM
- Displaying and Changing the OIM Reference
- Customizing the Process Display Screen
- Customizing the Function Keys
- Controlling the Drive From the OIM
- LiquiFlo 2.0 Drive Frame 3 Wiring Diagrams
- LiquiFlo 2.0 Drive Frame 4 Wiring Diagrams
- Index
- Back Cover

Rockwell Automation Publication D2-3518-3 - May 2013 65
Chapter 8
7 Input Voltage RS 109 Base Motor Freq 200 Reset Meters
8 Input Voltage ST 110 VML Ki 201 Language
9 Input Voltage TR 111 VML Kp 203 Drive Checksum
10 DC Bus Voltage 112 CML Ki 211 Drive Alarm
11 Active Voltage 113 CML Kp 214 Start Inhibits
12 Reactive Voltage 114 VML Reset Level 216 Dig In Status
13 Input kW 120 Cold Plate Temp 217 Dig Out Status
14 Input Pwr Factor 121 Invtr Base Temp 220 Fault Frequency
15 Motoring kWh 122 Rctfr Base Temp 221 Fault Amps R
16 Regen kWh 123 CPC K1 222 Fault Amps S
17 Elapsed Run Time 124 CPC K2 223 Fault Amps T
18 Rctfr Base Temp 125 High Temp Limit 224 Fault Amps Q
19 Rctfr IGBT Temp 126 Low Temp Limit 225 Fault Amps D
20 Rctfr IT Overld 127 Start Move Time 226 Fault Volts Vdc
21 Rctfr I2T Overld 128 Delay After Move 227 Fault Volts Q
22 Line I Imbalance 129 Ambient Temp 228 Fault Volts D
23 Line V Imbalance 150 Input Load Amps 234 Testpoint 1 Sel
26 Rated kW 151 Current Limit 235 Testpoint 1 Data
27 Rated Volts 152 Life KW H 236 Testpoint 2 Sel
28 Rated Amps 153 Life Run Time 237 Testpoint 2 Data
29 Control SW Ver 154 Life Power Time 238 Fault Config
60 V Imbalance Lmt 155 Life Power Cycle 240 Fault Clear
61 V Imbalance Time 156 DPI Error 241 Fault To Invertr
62 I Imbalance Lmt 157 CS Msg Rx Cnt 242 Power Up Marker
63 I Imbalance Time 158 CS Msg Tx Cnt 243
245
247
249
Fault 1 Code...
Fault 4 Code
64 Ride Through Ena 159 CS Timeout Cnt 244
246
248
250
Fault 1 Time...
Fault 4 Time
65 Ride Through Sec 160 CS MSG Bad Cnt 300 IOC Redir Time
100 Rectifier Contrl 161 PC MSG Rx Cnt 301 IOC Redir Max
101 Rectifier Status 162 PC MSG Tx Cnt 302 Service 302
102 Vdc Optimize 163 PC Timeout Cnt 303 Service 303