Instruction Manual

3-120
DBT Reach Drive User Manual
Displays the status bits for Torque Proving.
Displays the load side torque.
Sets the level at which the Torque Alarm becomes active.
Sets the drive action when the Torque Alarm is exceeded.
612 Torq Prove Sts
Range: See figure 3.41
Default: Read Only
Access: 2 Path: Applications>Torque Proving
See also:
Figure 3.41 – Torq Prove Sts
000
x
0000
xxxxxxxx
10 01234567891112131415
1
=Enabled
0
=Disabled
x = Reserved
Bit #
EndLimitActv
DecelLimActv
MicroPosActv
BrkSlipAlarm
Brake Set
LoadTestActv
RefLoadLimtd
631 Rod Load Torque
Range: 0.00 to 32000.00 ft-lb [0.01 ft-lb]
Default: Read Only
Access: 2 Path: Applications>Oil Well Pump
See also:
632 TorqAlarm Level
Range: 0.00 to 5000.00 ft-lb [0.01 ft-lb]
Default: 0.00 ft-lb
Access: 2 Path: Applications>Oil Well Pump
See also:
633 TorqAlarm Action
Range: 0 = No Action
1 = Goto Preset 1
Default: 0 = No Action
Access: 2 Path: Applications>Oil Well Pump
See also: