User Manual

Programming Reference 4-53
P.091 Diagnostics Display (continued)
displayed as a four-digit combination of 1s and 0s (1 = on, 0 = off) in the following
manner:
For example, if P.095 = 11.0 and P.005 = 110% if maximum, then the maximum output
current rating with no overload rating (100% rating) = 10.0 amps.
Four-Character Display
P.090 = 1, terminal strip digital inputs 4 3 2 1
P.090 = 2, terminal strip digital inputs 8 7 6 5
P.090 = 4, RMI digital inputs 4 3 2 1
P.095 Power Module Output Amps
This parameter
displays the
maximum output
current rating of the
drive. The maximum
value of Current Limit
(P.005) corresponds
to P.095.
Parameter Range: N/A
Default Setting: N/A
Parameter Type: Read only
Refer also to parameters: P.005 Current Limit
P.097 Custom Software Identification Number/Version
This parameter
displays the custom
software identification/
version number. The
identification number
4.xx is used for all
LiquiFlo drives.
Parameter Range: 4.01 to 4.99 (for LiquiFlo)
Default Setting: N/A
Parameter Type: Read only
Refer also to parameters: N/A
P.098 Software Version Number
This parameter
displays the software
version number.
Parameter Range: 6.40 to 6.49
Default Setting: N/A
Parameter Type: Read only
Refer also to parameters: N/A