User Manual
Publication LDL-UM001A-EN-P - March 2009 79
Sin/Cos Linear Encoder and Kinetix 6000 Drives Appendix C
3. Click the Drive/Motor tab.
4. Enter the following parameters.
5. Click the Conversion tab.
6. Enter the following parameters.
Parameter Value Comment
Driver Resolution 25600 For 40 µ pitch encoder scale.
51200 For 20 µ pitch encoder scale.
Drive Counts per Motor Millimeter –
Parameter Value Comment
Driver Resolution 25600 For 40 µ pitch encoder scale.
51200 For 20 µ pitch encoder scale.