User Manual
Publication LDL-UM001A-EN-P - March 2009 43
Configure and Start Up the LDL-Series Linear Motor Chapter 6
3. Using the screen image as a reference, configure the parameters
as shown in the Setting column.
4. Click OK.
5. Click the Motor Feedback tab.
Parameter Setting Comment
Loop Configuration Position Servo –
Drive Resolution 200 5 µm encoder
500 2 µm encoder
1000 1 µm encoder
2000 0.5 µm encoder
51200
20 µm pitch Sin/Cos encoder
(1)
(1) Requires custom database file contact Application Engineering at 631.444.6600.
25600 40 µm pitch Sin/Cos encoder
Drive Counts per Motor Millimeter –
Real Time Axis Information
Attribute 1 Position Feedback –