Cables Exit in the Center
If mounting coils in tandem, such that the power cables exit in the
center, as shown, use the following table to find mounting distance
and phase wiring.
160 (6.30) Red Red U
White White V
Black Black W
(1) Master has Hall effect module.
(2) Slave has no Hall effect module.
Phase Wiring for Right Exit Power Cables
L1
mm (in.)
Coil # 1
Master
(1)
Coil # 2
Slave
(2)
Amplifier
Phase
L1
Coil #1 is the master
Coil #1
Coil #2
Hall Effect
Phase Wiring for Center Exit Power Cables
L1
mm (in.)
Coil # 1
Master
(1)
Coil # 2
Slave
(2)
Amplifier
Phase
90 (3.54)
or
150 (5.91)
Red White U
White Red V
Black Black W
(1) Master has Hall effect module.