Quick Reference Guide Manual

Quick Reference Guide
W i r i n g /
Power Up /
Parameter Setting
Reliance Electric
GV6000 AC Drive
1/2 to 200 HP
Quick Reference Instructions:
A quick reference to some basic
configurations and drive features.
Volts/Hertz Regulation
Sensorless Vector Regulation
Flux Vector Regulation
D2-3544
OIM Keypad and Display
The supplied keypad and display allow for
setup, parameter adjustment, monitoring
and diagnostics.
Operator Interface Module (OIM)
NOTE: This material is not intended to provide
operational instructions. Appropriate Reliance
Electric Drives instruction manual information
and precautions should be studied prior to
installation, operation, or maintenance of
equipment.
Startup Menu
OIM Startup Menu
The Startup Menu parameters can be
accessed via the keypad tab menu. Once
into the selection list the following
parameters can be set to configure the
drive to the installed motor.
1. Quick Start
Regulation Type
Encoder PPR
Speed Units
Stop Type
Motor NP FLA
Maximum Speed
Minimum Speed
Accel Time
Decel Time
Speed Ref Select
Current Limit
The default configuration is defined as:
Drive Voltage Rating = Motor Voltage
Start/Stop control = OIM
Speed Reference = OIM
Control Mode = Sensorless Vector
If the drive default configuration is to be
used for initial startup then the above
parameters are the only settings required.
If the user needs to customize the drive
configuration different than the default
setting, then the user should verify
parameter settings accessible throughout
start-up menu.
2. Input Voltages
200/240, 400/480, and 600 VAC,
based on model number
3. Motor Nameplate Data
Motor NP Power
Motor NP FLA
Motor NP Volts
Motor NP Hertz
Motor NP RPM
Startup Menu
4. Motor Tests
Direction Test
Autotune
Inertia Test
5. Reference Setup
OIM Keypad, Analog Input, Network,
MOP, Frequency, Encoder, Presets
6. Configure I/O
Digital Inputs/Outputs
Analog Outputs
7. Step Saver, Applications
Control Mode
Motor Cntl Sel (53) performance can be
selected from:
Sensorless Vector (default)
High performance control without
encoder feedback
SV Economize
Sensorless vector with energy saving
Custom V/Hz
Basic open loop control. Multi-motor
application
Fan/Pump: V/Hz
Provides for a Fan load V/Hz curve
FVC Vector
Highest performance mode of control
acheived with encoder feedback
SEL
PARAM DIAGSTARTUP
Startup
SEL
PARAM DIAGSTARTUP
Parameters
SEL
PARAM DIAGSTARTUP
Diagnostics
Display
SEL
PARAM DIAG Display
Memory
SEL
Diag Display Memory
Password
SEL
Display Memory Psswrd
SEL
SEL
SEL
SEL
SEL
Quickstart
Motor Data
Motor Tests
Reference Setup
Configure I/O
Step Saver
Applications
Groups
Linear List
Changed Parameters
Alarms
Faults
Drive Status
Device Select
Device Name
Device Version
Device Items
Language
Disp Adjustments
Process Display
Reset Display
OIM CopyCat
Drive User Sets
Restore Defaults
Set Access Level
Set AccLvl Password
Set Wrt Prot Passwrd
Press to select a menu item.
SEL
Press to move between two menu tabs.
ESC
PROG
Press to move 1 level back in the menu structure.
Press to move between menu items.
!
ATTENTION: Rotation of the
motor in an undesired direction
can occur during these
procedures. Failure to observe
this precaution could result in
damage to equipment or bodily
injury.