User Manual Instruction Manual
13-46
GV6000 AC Drive User Manual
This is a typical setting, where minimum input (0 volts) represents 0 Hz and maximum
input (10 volts) represents 60 Hz (it provides 6 Hz change per input volt).
Analog Scaling
13.19.3.2 Configuration #2:
• Anlg In Config (320), bit 0 = “0” (Voltage)
• Speed Ref A Sel (90) = “Analog In 1”
• Speed Ref A Hi (91) = 30 Hz
• Speed Ref A Lo (92) = 0 Hz
• Analog In 1 Hi (322) = 10V
• Analog In 1 Lo (322) = 0V
Speed Ref A Sel (90) = “Analog In 1”
Analog In 1Hi (322)
10V
Speed Ref A Hi (91)
60 Hz
Analog In 1Lo (323)
0V
Speed Ref A Lo (92)
0 Hz
2
4
6
8
10
12
601218
Output Hertz
Input Volts
24 30 36 42 48 54 60