User Manual Instruction Manual

Application Notes
13-41
Actual Line Voltage, the maximum power the 5 HP, 460V motor can produce is3.7 HP
at 44.6 Hz.
13.19 Analog Inputs
13.19.1 Possible Uses of Analog Inputs
The analog inputs provide data that can be used for the following purposes:
Provide a value to Speed Ref A or Speed Ref B.
Provide a trim signal to Speed Ref A or Speed Ref B.
Provide a reference when the terminal block has assumed manual control of the
reference
Provide the reference and feedback for the PI loop. Refer to Process PI Loop in
section 2.3.19.
Provide an external and adjustable value for the current limit and DC braking level
Enter and exit sleep mode.
Provide a value to Torque Ref A or Torque Ref B.
13.19.2 Analog Input Configuration
Anlg In Config (320)
Current Lmt Sel (147) allows an analog input to control the set point while DC Brk Levl
Sel (157) allows an analog input to define the DC hold level used when Ramp-to-Stop,
Ramp-to-Hold, or Brake-to-Stop is active.
To provide local adjustment of a master command signal or to provide improved
resolution the input to analog channel 1 or 2 can be defined as a trim input. Setting
Trim In Select (117) allows the selected channel to modify the commanded frequency
by ±10%. The speed command will be reduced by 10% when the input level is at Anlg
In x Lo with it linearly increasing to 10% above command at Anlg In x Hi.
5 HP
3.7 HP
HP @ Motor (Drive Output)
Actual Line Voltage (Drive Input)
342V
460V
480V
528V
FV