Sets the time that the torque must exceed [TorqAlarm Level (632)] before TorqAlarm
Action (633) occurs.
Sets the amount of time a Torque Alarm can be active until timeout action begins.
Sets the drive action when TorqAlrm Timeout (635) is exceeded.
Displays the diameter of the sheave on the pump.
634 TorqAlarm Dwell
Range: 0.0 to 60.0 sec [0.1 sec]
Default: 0.0 sec
Access: 2 Path: Applications>Oil Well Pump
See also:
635 TorqAlrm Timeout
Range: 0.0 to 600.0 sec [0.1 sec]
Default: Read Only
Access: 2 Path: Applications>Oil Well Pump
See also:
636 TorqAlrm TO Act
Range: 0 = Resume
1 = Fault Drive
Default: 0 = Resume
Access: 2 Path: Applications>Oil Well Pump
See also:
637 PCP Pump Sheave
Range: 0.25 to 200.00 inches [0.01 inches]
Default: 20.0 Inch
Access: 2 Path: Applications>Oil Well Pump
See also: