User Manual Instruction Manual
Parameter Descriptions
11-115
Displays the status bits for Torque Proving.
Displays the load side torque.
Sets the level at which the Torque Alarm becomes active.
Sets the drive action when the Torque Alarm is exceeded.
612 Torq Prove Sts
Range: See figure 11.40
Default: Read Only
Access: 2 Path: Applications>Torque Proving
See also:
Figure 11.40 – Torq Prove Sts
000
x
0000
xxxxxxxx
10 01234567891112131415
1
=Enabled
0
=Disabled
x =Reserved
Bit #
EndLimitActv
DecelLimActv
MicroPosActv
BrkSlipAlarm
Brake Set
LoadTestActv
RefLoadLimtd
631 Rod Load Torque
Range: 0.00 to 32000.00 ft-lb [0.01 ft-lb]
Default: Read Only
Access: 2 Path: Applications>Oil Well Pump
See also:
632 TorqAlarm Level
Range: 0.00 to 5000.00 ft-lb [0.01 ft-lb]
Default: 0.00 ft-lb
Access: 2 Path: Applications>Oil Well Pump
See also:
633 TorqAlarm Action
Range: 0 = No Action
1 = Goto Preset 1
Default: 0 = No Action
Access: 2 Path: Applications>Oil Well Pump
See also: