User Manual Instruction Manual

Parameter Descriptions
11-111
Value of the signal being sent out of the Universal Scale Block. Typically this value is
used as the source of information and will be linked to another parameter.
Parameters 500 - 598 are found in the Advanced Tuning Parameters
Section (Section 11.2).
Enables/disables torque/brake proving feature. When Enabled, Digital Out1 Sel (380)
becomes the brake control.
This value is not changed when parameters are reset to factory defaults.
Enable = Enables Torque Proving features.
Encoderless = Enables encoderless operation - bit 0 must also be enabled.
MicroPosSel = A “1” allows the Micro Position digital input to change the speed
command while the drive is running.
Preload Sel = “0” uses the last torque for preload. “1” uses “TorqRef A” if commanded
direction is forward and “TorqRef B” for reverse.
481
487
493
499
Scale1 Out Value
Scale2 Out Value
Scale3 Out Value
Scale4 Out Value
Range: -/+ 32767.000 [0.001]
Default: Read Only
Access: 2 Path: Utility>Scaled Blocks
See also:
600 TorqProve Cnfg
Range: See figure 11.38
Default: See figure 11.38
Access: 2 Path: Applications>Torque Proving
See also:
Figure 11.38 – TorqProve Cnfg
000000
xxxxxxxxxx
10 01234567891112131415
1
=Enabled
0
=Disabled
x =Reserved
Bit #
Factory Default Bit Values
Enable
Encoderless
MicroPosSel
Preload Sel
Load Spd Lim
NoEnclsBkSlp