Example:
Mask OR: If any bits in the value are set in the mask, then the output is On.
Mask AND: If all bits in the value are set in the mask, then the output is On.
Selects the encoder type - single channel or quadrature. Options 1 and 3 detect a
loss of encoder signal (when using differential inputs) regardless of the Feedback
Select (80) setting.
For FVC Vector mode, use a quadrature encoder only (option 0 or 1).
If a single channel encoder is used (option 2 or 3) in sensorless vector or V/Hz mode,
select 2 = Reverse Dis in Direction Mode (190).
Figure 11.36 – Dig Out Mask
Selected Value0000110011110000
Mask 0 0 0 0 0 0 0 0 1 0 0 0 0 1 0 0
Result Output On
Selected Value0000110011110000
Mask 0 0 0 0 0 0 0 0 1 0 0 0 0 1 0 0
Result Output Off
00
x
0
xxxxxxxxxxxx
10 01234567891112131415
1
=Output Energized
0
=Output De-energized
x =Reserved
Bit #
Net DigOut1
Net DigOut2
Net DigOut3
412 Motor Fdbk Type
Range: 0 = Quadrature
1 = Quad Check
2 = Single Chan
3 = Single Check
Default: 0 = Quadrature
Access: 0 Path: Motor Control>Speed Feedback
See also: