Reference Manual User Manual
4-2
GV3000/SE AC Bookshelf Drive Software Reference, Version 6.06
4.2 Parameter Types
There are three types of parameters:
Configurable:
These parameters can be adjusted or changed only while the drive is
stopped.
Tunable:
These parameters can be adjusted or changed while the drive is running or
stopped.
Read only:
These parameters cannot be adjusted.
Each parameter is described in detail in this chapter. The following information is
provided for each parameter:
Parameter Number:
the unique number assigned to a specific parameter. The
number is preceded by either P, H, U, or r to identify it as a General, Volts/Hertz,
Vector, or optional RMI parameter, respectively. The parameter number is
displayed on the drive’s keypad/display.
Figure 4.1 – Parameter Menu Structure