Reference Manual User Manual

Using the Keypad/Display to Program, Monitor, and Control the Drive
3-9
3.7 Monitor Mode LEDs
Table 3.3 describes the values that will be displayed when the corresponding monitor
mode LED is on.
Table 3.3 Monitor Mode LEDs
Monitor Mode LED Corresponding Display When LED Is On (Actual Values)
RPM Motor speed is displayed. This value is scaled in parameter
P.028.
V Drive output volts are displayed. This value is
not
DC bus
volts.
A Drive output amps are displayed.
Hz Drive output frequency in hertz is displayed.
kW Output power of the drive in kilowatts is displayed. Note that
this is intended for display purposes as a general indication
of kilowatt output and should not be used for control or exact
metering purposes.
TRQ Motor output torque is displayed in percent. (Valid only for
vector regulation).
ALL LEDs Selected speed reference (in P.028 units) or torque
reference (in %) is displayed.