See Appendix H for the complete block diagram.
This parameter allows multiple drive sections with a common line reference, but with
different values for draw gain, to run at different speeds depending on the percent
draw.
Note that P.016 affects the accel/decel times. As draw gain increases positive, the
accel/decel time decreases proportionately. As draw gain increases negative, the
accel/decel time increases proportionately. This is based on the following formula:
Modified Accel/Decel = Accel/Decel x [1 / (1.00 + (Draw% / 100))]
P.015 Trim Gain Percentage
This parameter
specifies a
percentage of the
selected trim
reference entering
the speed regulator.
See figure 4.4.
Parameter Range:
-100.0% to +100.0% (1.0 = 1%)
Default Setting:
0.0
Parameter Type:
Tunable
Refer also to parameters:
P.014 Trim Reference Source
Figure 4.4 – Draw and Trim Gain
P.016 Draw Gain Percentage
This parameter is
used to increase or
decrease the
selected speed
reference to the
speed regulator.
Parameter Range:
-100.0% to +100.0% (1.0 = 1%)
Default Setting:
0.0
Parameter Type:
Tunable
Refer also to parameters:
N/A