Reference Manual User Manual

4-24
GV3000/SE AC Bookshelf Drive Software Reference, Version 6.06
See Appendix H for the complete block diagram.
This parameter allows multiple drive sections with a common line reference, but with
different values for draw gain, to run at different speeds depending on the percent
draw.
Note that P.016 affects the accel/decel times. As draw gain increases positive, the
accel/decel time decreases proportionately. As draw gain increases negative, the
accel/decel time increases proportionately. This is based on the following formula:
Modified Accel/Decel = Accel/Decel x [1 / (1.00 + (Draw% / 100))]
P.015 Trim Gain Percentage
This parameter
specifies a
percentage of the
selected trim
reference entering
the speed regulator.
See figure 4.4.
Parameter Range:
-100.0% to +100.0% (1.0 = 1%)
Default Setting:
0.0
Parameter Type:
Tunable
Refer also to parameters:
P.014 Trim Reference Source
Figure 4.4 Draw and Trim Gain
P.016 Draw Gain Percentage
This parameter is
used to increase or
decrease the
selected speed
reference to the
speed regulator.
Parameter Range:
-100.0% to +100.0% (1.0 = 1%)
Default Setting:
0.0
Parameter Type:
Tunable
Refer also to parameters:
N/A