Step 5.19 Press the ENTER key.
The default setting is 0.
Step 5.20 Press the
▲
key to increase the selection value, or leave it at 0.
If you do not have AC input or you are using a snubber resistor, see the
H.017 parameter description for more information.
The adjustment range is:
0 = AC input; snubber resistor not used;
ride-through enabled.
1 = AC input; snubber resistor used;
ride-through enabled.
2 = DC input; snubber resistor not used;
ride-through disabled.
3 = DC input; snubber resistor used;
ride-through disabled.
4 = DC input; snubber resistor not used;
ride-through enabled.
5 = DC input; snubber resistor used;
ride-through enabled.