Software Start-Up and Ref. Manual Owner manual

C-2
GV3000/SE AC Drive Software Reference, Version 6.06
Second Menu General Parameters (USA Defaults)
Second Menu Volts/Hertz Parameters (USA Defaults)
Second Menu Vector Parameters (USA Defaults)
Parameter
No.
Parameter
Name
Power Module
25G4160
25G4260
25V4160
25V4260
30V4160
30V4260
40V4160
40V4260
50V4160
50V4260
50R4160
50T4160
60G4160
60G4260
75R4160
75T4160
P.047 Carrier Freq.
(kHz)
8888 8 2 8 2
Parameter
No.
Parameter
Name
Power Module
25G4160
25G4260
25V4160
25V4260
30V4160
30V4260
40V4160
40V4260
50V4160
50V4260
50R4160
50T4160
60G4160
60G4260
75R4160
75T4160
H.002 Motor Namepl.
Amps
29.7 29.7 35.5 48.7 62.5 68.0 68.0 85.1
Parameter
No.
Parameter
Name
Power Module
25G4160
25G4260
25V4160
25V4260
30V4160
30V4260
40V4160
40V4260
50V4160
50V4260
50R4160
50T4160
60G4160
60G4260
75R4160
75T4160
U.004 Motor Namepl.
Amps
27.0 30.0 35.5 48.7 62.5 65.0 65.0 77.0
U.005 Motor Namepl.
RPM
1770 1770 1770 1775 1775 1780 1780 1780
U.006 Magnetizing
Current
52.0 44.0 44.0 47.0 44.0 49.0 49.0 46.0
U.012 Speed Reg.
Prop. Gain
5.00 5.00 5.00 5.00 5.00 10.00 5.00 10.00
U.013 Speed Reg. Int.
Gain
5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00
U.014 Torque Reg.
Prop. Gain
0.40 0.40 0.40 0.40 0.40 0.20 0.40 0.20
U.015 Torque Reg.
Integral Gain
200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
U.016 Field Weaken
Start RPM
1770 1770 1770 1775 1775 1780 1780 1780
U.017 Motor Top
Speed
1770 1770 1770 1775 1775 1780 1780 1780
U.019 Flux Current
Reg. Prop. Gain
0.30 0.30 0.30 0.30 0.30 0.15 0.30 0.15
U.20 Flux Current
Reg. Int. Gain
50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0
U.21 Rotor Time
Constant
250 250 250 250 250 350 250 350
U.022 Motor Namepl.
HP
20.0 25.0 30.0 40.0 50.0 60.0 50.0 75.0
U.032 SVC Flux Curr.
Reg. Gain
900 850 800 750 700 650 700 600