Software Start-Up and Ref. Manual Owner manual
Power Module-Dependent Parameter Default Values
C-1
A
PPENDIX
C
Power Module-Dependent
Parameter Default Values
Second Menu General Parameters (USA Defaults)
Second Menu Volts/Hertz Parameters (USA Defaults)
Second Menu Vector Parameters (USA Defaults)
Parameter
No.
Parameter
Name
Power Module
1V4160
1V4460
2V4160
2V4460
3V4160
3V4460
5V4160
5V4460
7V4160
7V4260
10V4160
10V4260
15V4160
15V4260
20V4160
20V4260
P.047 Carrier Freq.
(kHz)
8888 8 8 8 8
Parameter
No.
Parameter
Name
Power Module
1V4160
1V4460
2V4160
2V4460
3V4160
3V4460
5V4160
5V4460
7V4160
7V4260
10V4160
10V4260
15V4160
15V4260
20V4160
20V4260
H.002 Motor Namepl.
Amps
1.3 2.7 3.8 6.1 9.0 11.9 17.8 24.0
Parameter
No.
Parameter
Name
Power Module
1V4160
1V4460
2V4160
2V4460
3V4160
3V4460
5V4160
5V4460
7V4160
7V4260
10V4160
10V4260
15V4160
15V4260
20V4160
20V4260
U.004 Motor Namepl.
Amps
1.6 3.0 4.4 7.1 11.1 13.8 20.5 27.0
U.005 Motor Namepl.
RPM
1736 1744 1726 1722 1778 1777 1780 1777
U.006 Magnetizing
Current
51.2 59.4 56.7 54.5 60.3 52.8 52.1 52.0
U.012 Speed Reg.
Prop. Gain
5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00
U.013 Speed Reg. Int
Gain
5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00
U.014 Torque Reg.
Prop. Gain
0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40
U.015 Torque Reg.
Integral Gain
200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
U.016 Field Weaken
Start RPM
1736 1744 1726 1722 1778 1777 1780 1777
U.017 Motor Top
Speed
1736 1744 1726 1722 1778 1777 1780 1777
U.019 Flux Current
Reg. Prop. Gain
0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30
U.20 Flux Current
Reg. Int. Gain
50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0
U.21 Rotor Time
Constant
250 250 250 250 250 250 250 250
U.022 Motor Namepl.
HP
1.0 2.0 3.0 5.0 7.5 10.0 15.0 20.0
U.032 SVC Flux Curr.
Reg. Gain
1000 1000 1000 1000 1000 1000 950 900