Owner's manual

Table Of Contents
2-20
GV3000/SE AC Drive ControlNet Network Communication Option Board
Step 4.6 Fasten the left side of the ControlNet option board to the keypad bracket
using the two plastic rivets.
Step 5. Reinstall the Keypad Bracket in the Drive
Step 5.1 Align the Regulator board ribbon cable connector with the connector to the
Base board. Carefully press the ribbon cable connector in until the retaining
clips lock into place.
Step 5.2 Place the keypad bracket back into position.
Step 5.3 If the drive has:
A Regulator board cover and terminal cover: Replace the Regulator board
cover. Fasten it using the three M4 screws removed earlier.
Only a terminal cover: Use a long magnetized screwdriver to fasten the
four screws that hold the keypad bracket. Replace the side cover on the
drive.
Step 5.4 Route the Network Drop Cable through the left-most opening at the bottom
of the drive.
Step 5.5 Connect the brown wire to terminal 1 of the 2-connector terminal strip.
Connect the white wire to terminal 2.
Step 5.6 Reconnect any wiring that was removed from the Regulator board.
Step 5.7 Replace the terminal cover (below the keypad). Fasten it using the two M4
screws removed earlier.
This completes the hardware installation of the ControlNet option board. Do not
remove the lockout and tag until you have completed section 2.9, which provides
instruction on connecting to the ControlNet network.