User Manual
B-4
AutoMax Network Communication Option Board for the GV3000/SE AC Drive
Network speed PI limit control enable n/a 1 53 2
nld (Identification request not performed) 1 13 3 n/a
Number of error log entries 1 14 0 to 7 n/a
NVRAM write failure (EEr)
1135n/a
OC (overcurrent, steady state) 1 12 0 n/a
OCA (overcurrent, at acceleration) 1 12 1 n/a
OCb (overcurrent, at DC braking) 1 12 3 n/a
OCd (overcurrent, at deceleration) 1 12 2 n/a
OF (overfrequency) 1 12 15 n/a
OH (drive overtemperature) 1 12 7 n/a
OL (electronic thermal overload) 1 12 6 n/a
OPL (motor output phase loss) 1 12 14 n/a
Option port speed PI high limit n/a 1 59
Option port speed PI low limit n/a 1 60
Option port speed/torque direct ref n/a 1 33
Option port trim ref (when P.014=2) n/a 1 34
Option Port: Com Loss Response (P.062) 1 29 1 62
Option Port: Network Ref Source (P.063) 1 30 0 to 7 1 63 0 to 7
Option Port: Netw Trim Ref Source (P.064) 1 30 8 to 15 1 63 8 to 15
Option Port: Type and Version (P.065) 2 31 n/a
OSP (overspeed; vector only) 1 12 13 n/a
Outer control loop (OCL) enable n/a 1 32 5
Outer control loop enabled 1 26 2 n/a
OCL Feedback (U.040) 3, Vector 0 8 to 15 1 58 8 to 15
OCL Integral Gain (U.046) 3, Vector 27 3, Vector 61
OCL direct reference n/a 1 34
OCL Lead/Lag Low Freq. (U.042) 3, Vector 23 3, Vector 57
OCL Lead/Lag Ratio (U.043) 3, Vector 24 3, Vector 58
OCL Lead/Lag Select (U.041) 3, Vector 21 8 to 15 3, Vector 54 8 to 15
OCL Proportional Gain (U.045) 3, Vector 26 3, Vector 60
OCL Proportional Trim Enable (U.048) 2 19 4 2 40 4
OCL Reference Gain (U.044) 3, Vector 25 3, Vector 59
OCL Trim Range Percentage (U.047) 3, Vector 30 3, Vector 62
Output Current 1 7 n/a
Output Phase Loss Enable (P.045) 2 24 1 2 38 1
Output Relay Configuration (P.013) 2 9 1 56
Output speed/frequency (
RPM display)
15 n/a
Output voltage (VOLTS display)
16 n/a
Overcurrent, at acceleration (OCA) 1 12 1 n/a
Overcurrent, at DC braking (OCb) 1 12 3 n/a
Overcurrent, at deceleration (OCd) 1 12 2 n/a
Overcurrent, steady state (OC) 1 12 0 n/a
Overfrequency (OF) 1 12 15 n/a
Overfrequency Limit (H.022) 3, V/Hz 22 3, V/Hz 54
Overspeed; vector only (OSP) 1 12 13 n/a
P.000, Control Source 1 16 n/a
P.001, Accel Time 1 (RAMP 1) 1 17 1 37
P.002, Decel Time (RAMP 1) 1 18 1 38
P.003, Minimum Speed 1 19 1 39
P.004, Maximum Speed 1 20 1 40
P.005, Current Limit 1 21 1 41
Description or GV3000/SE Parameter
Read Only Read/Write
Drop Register Bit Drop Register Bit