User Manual

A-4
AutoMax Network Communication Option Board for the GV3000/SE AC Drive
42
Terminal Strip Analog Input Offset (P.009)
Line Dip Ride-Through Time (P.042) Motor Top Speed (U.017) Avoidance Frequency Midpoint 1 (H.010)
43
Terminal Strip Analog Input Gain (P.010)
Fault Auto Reset Attempts (P.043) AC Line Volts (U.018) Avoidance Frequency Band 1 (H.011)
44
TS Analog Input Configure (P.011) Fault Auto Reset Time (P.044) Flux Current Regulator Prop. Gain (U.019) Avoidance Frequency Midpoint 2 (H.012)
45
Trim Gain Percentage (P.015)
Network Out Register Sources
(
P.066, P.067
)
Flux Current Regulator Integral Gain (U.020)
Avoidance Frequency Band 2 (H.013)
46
Draw Gain Percentage (P.016)
Network Out Register Sources (P.068, P.069)
Rotor Time Constant (U.021) Avoidance Frequency Midpoint 3 (H.014)
47
Speed Reg. Proportional Gain (U.012) Carrier Frequency (kHz) (P.047) Motor Nameplate Horsepower (U.022) Avoidance Frequency Band 3 (H.015)
48
Speed Regulator Integral Gain (U.013) Reserved Zero Speed Hold Time (U.025) Sync Direction (H.016)
49
Jog Speed Reference (P.020) Country Defaults (P.049) Current Compounding Gain (U.026)
Input Power/Snubber Configuration (H.017)
50 Stop Type (P.025) Reserved Inertia Compensation Gain (U.027) Volts/Hertz Curve Type (H.018)
51
Function Loss Response (P.026) Reserved Losses Compensation Gain (U.028) Reserved
52
Speed Display Scaling (P.028) Reserved Reserved Reserved
53
Elapsed Time Meter Reset (P.030) (bit0)
Network inertia comp enable (bit 1)
Network speed PI limit control en (bit2)
Reserved
SVC Slip Adjust (U.030)
AC Line Volts (H.021)
54 Reserved Reserved
SVC Sync Direction (U.031) (bits 0 to 7)
OCL Lead/Lag Select (U.041) (bits 8 to 15)
Overfrequency Limit (H.022)
55 Reserved Reserved
SVC Flux Current Regulator Gain U.032 Reserved
56
Output Relay Configuration (P.013) Reserved Reserved Reserved
57
Trim Reference Source (P.014) Reserved
OCL Lead/Lag Low Frequency (U.042)
Reserved
58
Torque Ref. Source (U.000) (bits0to7)
OCL Feedback Select (U.040) (bits8to15)
Reserved OCL Lead/Lag Ratio (U.043) Reserved
59 Option port speed PI high limit Reserved
OCL Reference Gain (U.044)
Reserved
60 Option port speed PI low limit Reserved
OCL Proportional Gain (U.045)
Reserved
61
Network Connection Type (P.061) Reserved OCL Integral Gain (U.046) Reserved
62
Communication Loss Response (P.062)
Reserved OCL Trim Range Percentage (U.047) Reserved
63
Network Reference Sources (P.063, P.064)
Reserved Reserved Reserved
Table A.2 – Register Map Summary (Continued)
Reg
Description or GV3000 Parameter
Drop_1 Drop_2 Drop_3 (Vector) Drop_3 (V/Hz)