User Manual

5-14
AutoMax Network Communication Option Board for the GV3000/SE AC Drive
48 Zero Speed Hold Time (U.025) 1 = 0.1 seconds T
49 Current Compounding Gain (U.026). 1 = 0.001 T
50 Inertia Compensation Gain (U.027). 1 = 0.001 T
51 Losses Compensation Gain (U.028). 1 = 0.001 T
52 Reserved Must be 0
53 SVC Slip Adjust (U.030) 1 = 0.01 T
54 0 to 7 SVC Sync Direction (U.031) See drive software instruction manual C
8 to 15 Outer Control Loop Lead/Lag Select (U.041) 0 = bypass; 1 = lead/lag; 2 = lag/lead T
55 SVC Flux Current Regulator Gain (U.032) 1 = 1 rad/s T
56 Reserved Must be 0
57 Outer Control Loop Lead/Lag Low Frequency (U.042) 1 = 0.01 rad/s T
58 Outer Control Loop Lead/Lag Ratio (U.043) 1 = 1 T
59 Outer Control Loop Reference Gain (U.044) 1 = 0.001 T
60 Outer Control Loop Proportional Gain (U.045) 1 = 0.01 T
61 Outer Control Loop Integral Gain (U.046) 1 = 0.01 T
62 Outer Control Loop Trim Range Percentage (U.047) 1 = 0.001 T
63 Reserved Must be 0
Table 5.7 – Register Assignments for Drop_3 Area (Vector) Read/Write Registers (Continued)
Register Bit Description or GV3000/SE Parameter Settings Update*
*Update Times: C=350ms or less when tune/config enable is on and the drive is stopped. T=350ms or less when tune/config enable is on.