User Manual

5-2
AutoMax Network Communication Option Board for the GV3000/SE AC Drive
Table 5.2 – Register Assignment for Drop_1 Area Read Only Registers
Register Bit Description or GV3000/SE Parameter Settings Update*
0 Status word 1 (includes terminal strip digital inputs) 5ms
0 Drive ready 5ms
1 Drive running 5ms
2 Fault active 5ms
3 Run/jog mode status 1 = Jog 5ms
4 Forward/reverse reference invert command 1 = Reverse 5ms
5 Stop sequence in progress 5ms
6 Tune/config input enable (copied from Drop_1, register 32, bit 14) 5ms
7 Tune/config update synchronization flag (copied from Drop_1, register 32, bit 15) 5ms
8 Terminal strip digital input 1 (start) 5ms
9 Terminal strip digital input 2 (stop) 5ms
10 Terminal strip digital input 3 (fault reset) 5ms
11 Terminal strip digital input 4 (run/jog select) 5ms
12 Terminal strip digital input 5 (function loss) 5ms
13 Terminal strip digital input 6 5ms
14 Terminal strip digital input 7 5ms
15 Terminal strip digital input 8 5ms
1 Selected speed reference value Vector: 4095=Motor Top Speed (U.017)
V/Hz:4095=Maximum Speed (P.004)
5ms
2 Speed reference sum. Limit block output, including trim and draw 5ms
3 Speed feedback Vector: 4095 =Motor Top Speed (U.017) 5ms
4 Terminal strip analog input value (conditioned with offset, gain, and inversion) ±4095 = ±10V 5ms
5 Output speed/frequency (front panel RPM display) 5ms
6
Output voltage (front panel
VOLTS display)
5ms
7
Output current (front panel
AMPS display = amps x 10)
5ms
8 Network output register 1 (value determined by Drop_2, register 45, bits 0 to 7, (P.066)) 5ms
9 Network output register 2 (value determined by Drop_2, register 45, bits 8 to 15 (P.067)) 5ms
10 Network output register 3 (value is determined by Drop_2, register 46, bits 0 to 7 (P.068)) 5ms
11 Network output register 4 (value determined by Drop_2, register 46, bits 8 to 15 (P.069)) 5ms
*Update Times: 5 ms = 5 ms. 350 ms = 350ms or less.