Software Start-Up and Ref. Owner manual
Table Of Contents
- GV3000/SE AC General Purpose (V/Hz) and Vector Duty Drive, 1 - 20 HP, 230V AC Software Start-Up and Reference Manual D2-3387-5
- Important User Information
- Document Update
- Summary of Changes
- Table of Contents
- List of Figures
- List of Tables
- Preface
- Chapter 1 - Starting Up the Drive for Volts/Hertz Regulation
- Chapter 2 - Starting Up the Drive for Vector Regulation
- Chapter 3 - Using the Keypad/Display To Program, Monitor, and Control the Drive
- Chapter 4 - Programming Reference
- Chapter 5 - Troubleshooting the Drive Using Error Codes
- Appendix A - Alphabetical Listing of Parameters
- Appendix B - Record of User Parameter Settings
- Appendix C - Power Module-Dependent Parameter Default Values (230 V Series)
- Appendix D - Default Parameter Settings
- Appendix E - Configuring the Digital Inputs When the RMI Board Is Installed in the Drive
- Appendix F - Using the Terminal Strip Analog Input
- Appendix G - Drive Regulation Overview
- Back Cover / Publication D2-3387-5 July 2013

D-2
GV3000/SE 230 VAC Drive, Software Reference Version 6.04
Second Menu General Parameters (Continued)
Parameter Name
Speed Display Scaling P.048 = U-H
P.048 = UEC
Elapsed Time Meter
Elapsed Time Meter Reset
Preset Speed 1 P.048 = U-H
P.048 = UEC
Preset Speed 2 P.048 = U-H
P.048 = UEC
Preset Speed 3 P.048 = U-H
P.048 = UEC
Preset Speed 4 P.048 = U-H
P.048 = UEC
Preset Speed 5 P.048 = U-H
P.048 = UEC
Preset Speed 6 P.048 = U-H
P.048 = UEC
Preset Speed 7 P.048 = U-H
P.048 = UEC
Preset Speed 8 P.048 = U-H
P.048 = UEC
Encoder Loss Enable
Motor Overload Enable
Motor Overload Type
Line Dip Ride-Through Time
Fault Auto Reset Attempts
Fault Auto Reset Time
Output Phase Loss Enable
Carrier Frequency (kHz)
V/Hz or Vector Regulation
Country Defaults
Restore Defaults
Programming Disable
AUTO/MAN Key Disable
Manual Reference Preset Enable
Level Sense Start Enable
STOP/RESET Key Disable
Network Drop Number
Network Connection Type
Option Port: Communication Loss
Parameter
No.
P.028
P.029
P.030
P.031
P.032
P.033
P.034
P.035
P.036
P.037
P.038
P.039
P.040
P.041
P.042
P.043
P.044
P.045
P.047
P.048
P.049
P.050
P.051
P.052
P.053
P.054
P.055
P.060
P.061
P.062
1 : Parameter default is Power Module-dependent.
USA
(P.049 = USA)
1800
1
N/A
OFF
5.0 Hz
150 RPM
5.0 Hz
150 RPM
5.0 Hz
150 RPM
5.0 Hz
150 RPM
5.0 Hz
150 RPM
5.0 Hz
150 RPM
5.0 Hz
150 RPM
5.0 Hz
150 RPM
OFF
ON
FC
5.0
0
8
ON
8
U-H
USA
OFF
0
OFF
OFF
OFF
OFF
1
0
0
EUROPE
(P.049 = EUr)
1500
1
N/A
OFF
5.0 Hz
150 RPM
5.0 Hz
150 RPM
5.0 Hz
150 RPM
5.0 Hz
150 RPM
5.0 Hz
150 RPM
5.0 Hz
150 RPM
5.0 Hz
150 RPM
5.0 Hz
150 RPM
OFF
ON
FC
5.0
0
8
ON
8
U-H
EUr
OFF
0
ON
OFF
OFF
OFF
1
1
0
JAPAN
(P.049 = JPn)
1
1500
N/A
OFF
5.0 Hz
150 RPM
5.0 Hz
150 RPM
5.0 Hz
150 RPM
5.0 Hz
150 RPM
5.0 Hz
150 RPM
5.0 Hz
150 RPM
5.0 Hz
150 RPM
5.0 Hz
150 RPM
OFF
ON
FC
5.0
0
8
ON
8
UEC
JPn
OFF
0
OFF
OFF
OFF
OFF
1
0
0