Software Start-Up and Ref. Owner manual
Table Of Contents
- GV3000/SE AC General Purpose (V/Hz) and Vector Duty Drive, 1 - 20 HP, 230V AC Software Start-Up and Reference Manual D2-3387-5
- Important User Information
- Document Update
- Summary of Changes
- Table of Contents
- List of Figures
- List of Tables
- Preface
- Chapter 1 - Starting Up the Drive for Volts/Hertz Regulation
- Chapter 2 - Starting Up the Drive for Vector Regulation
- Chapter 3 - Using the Keypad/Display To Program, Monitor, and Control the Drive
- Chapter 4 - Programming Reference
- Chapter 5 - Troubleshooting the Drive Using Error Codes
- Appendix A - Alphabetical Listing of Parameters
- Appendix B - Record of User Parameter Settings
- Appendix C - Power Module-Dependent Parameter Default Values (230 V Series)
- Appendix D - Default Parameter Settings
- Appendix E - Configuring the Digital Inputs When the RMI Board Is Installed in the Drive
- Appendix F - Using the Terminal Strip Analog Input
- Appendix G - Drive Regulation Overview
- Back Cover / Publication D2-3387-5 July 2013

4-16
GV3000/SE 230 VAC Drive, Software Reference Version 6.04
P.007 Terminal Strip Digital Inputs Configure
(continued)
TRQ/SPD
TRQ/SPD allows you to switch between torque regulation and speed regulation
while the drive is running or stopped. This feature only applies when the drive has
been configured as a vector regulator (P.048 = UEC), and U.000 (Torque Reference
Source) > 0.
To provide smooth transitioning when switching from torque to speed, the speed
regulator is preset with the last torque reference. When switching from speed to
torque, the torque regulator will switch to the new torque reference.
The digital input for TRQ/SPD is active if the control source is local, remote, or serial.
Interaction with P.008
The default value of 0 for P.007 will limit P.008 (Terminal Strip Speed Reference
Source) to a selection of 0. You must change P.007 to some value other than 0 in
order to change P.008 to some value other than 0. See table 4.3 and the selection
example in the P.008 parameter description.
Refer to the GV3000/SE hardware reference manual for terminal strip wiring.