54 Configuring Control Options
Note: The number of M0 and M1 words specified above should
match the number of words set in the SPIO section of your
SLC 500 program software.
5. Select OK. The selected options are stored as part of the current GML
Commander diagram. The dialog box closes.
Configuring the AxisLink Interface
AxisLink allows you to link multiple controllers together to exchange
position and I/O information.
To configure your system for AxisLink:
1. Select AxisLink in the Configure Control Options dialog box.
2. Select the AxisLink tab. The AxisLink page appears.
M0 Floats Type the number of floats you need in the M0
file.
M0 Integers Type the number of integers you need in the
M0 file.
M1 Floats Type the number of floats you need in the M1
file.
M1 Integers Type the number of integers you need in the
M1 file.
Field Description