Reference Manual Owner's manual
Publication GMLC-5.2 - November 1999
426 Display and Operator Interface Blocks
Field Legends
Each field in the runtime display has an associated label, or legend. The
legend may be up to 24 characters long and may contain any legal ASCII
character (see Appendix B for an ASCII reference table) except those
shown in the following table
Axis status is displayed as a text message as shown in the following table.
The status conditions are prioritized from highest to lowest in the order
shown in the table. The higher the status value, the higher its priority (or
severity). In other words, a hardware overtravel fault has higher priority
than a software travel limits fault.
Illegal ASCII Legend Characters
ASCII Keyboard Decimal Hex Description
LF CTRL-j 10 0A Line Feed
ESC CTRL-[ 27 1B Escape
Axis Status Field Messages
Runtime
Display Description
AXL FLT AxisLink Timeout
AXL FLT AxisLink Fault (axis not found)
AXS OFF Virtual Axis Not Enabled
DRV FLT Drive Fault
ERR FLT Position Error Tolerance Fault
HRD LIM Hardware Overtravel Fault
SFT LIM Software Travel Limits Fault
ENC FLT Encoder Noise or Loss Fault
SRV OFF Feedback OFF or Virtual Axis Enabled
OUT LIM Servo Output Limited