User Manual

WebPak 3000 Drives: Register Map
7-15
Table 7.11 – WebPak 3000 Register Map, Drop_3: Master Read Registers, FULL Connection. Runtime Signal Data (Drive Output Data)
Register Bit Parameter Name (Number) Description Settings
0 J11 ANLG TACH VLT SCL (P.792) Position to set J11 jumper 16; 31; 62; 126; 250
1
J14 ANLG TACH VLT RNG (P.793) Position to set J14 jumper LOW; HIGH
2 J15 REGULATOR TYPE (P.799) Indicates position of jumper J15 SPEED/VOLTAGE; CURRENT/TORQUE
3 J18 ARM I FB RESISTOR (P.395) Indicates the burden resistor position 1 (15 ohm); 2 (20 ohm) 3 (30 ohm); 4 (39
ohm)
4 JOG RAMP OUTPUT (P.294) Jog ramp reference value immediately after the jog ramp
function
5
LEVEL DETECT 1 OUTPUT (P.648) Output of level detector 1 ON, OFF
6 LEVEL DETECT 2 OUTPUT (P.649) Output of level detector 2 ON OFF
7 LOSSES COMPENSATION (P.316) Output of the losses compensation calculator
8
NETW COMM STATUS (P.908) Status of network communication NOT ACTIVE, ACTIVE
9 NETW TYPE & VERSION (P.909) Type of network board installed and its software version
10
POS LL RATIO OUT (P.247) Value of the position loop lead/lag ratio
11
POS LL WLO OUT (P.246) Value of the position loop lead/lag low frequency
12
POS LOOP ERROR (P.254) Position loop error signal (difference between POSITION
REFERENCE (P.240) and position feedback)
13
POS PI KP OUT (P.248) Value of the position loop PI proportional gain
14
POS PI WLD OUT (P.249) Value of the position loop PI lead frequency
15
POS RAMP OUTPUT (P.237) Output of the position major loop ramp block
16
ROLL DIAMETER (P.865) Value of the calculated roll diameter in same units used
for
EMPTY CORE DIAMETER (P.830) and FULL ROLL
DIAMETER (P.125)
17
SPD SOURCE SELECT OUT (P.193) Selected speed reference source used as input to the
speed reference ramp section (rpm or user-defined
units)
18
SPEED CROSS OVER (P.133) Speed loop cross over frequency
19
SPEED LAG FREQ OUT (P.252) Value of the speed loop lag frequency
20
SPEED PI KP OUT (P.251) Value of the speed loop PI proportional gain
21
SPEED PI WLD OUT (P.250) Value of the speed loop PI low freuqncy
22
SPEED RAMP INPUT TP (P.198) Value of the speed reference signal immediately before
the speed loop
S-CURVE block
Runtime signal data are updated by the regulator every 10 msec.