User Manual
7-8
AutoMax Network Communication Option Board
14 Alarm latch bits word Bit-packed word containing latched alarm bits
0
MOTOR BRUSH WEAR LOW (A00001)
1
AC LINE VOLTAGE LOW (A00002)
2
AC LINE VOLTAGE HIGH (A00003)
3 to15 Reserved
15 Last alarm Alarm code of the most recent alarm
16
CONTROL SOURCE SELECT (P.000) Selected source for drive control signals
0=
TERMBLK
; 1=
KEYPAD
; 2=
SERIAL
; 3=
NETWORK
17 to 25 Runtime parameters see table 7.2
26 Reserved
27 Stop cause
28 Param Proc Error Number
29
NETW CONNECT TYPE (P.910) AutoMax network connection type BASIC; FULL
30 AMX NETW REF SELECT (P.911) AutoMax network reference selection DIRECT; BROADCAST N (N=1 TO 8)
31
REGULATOR SW VERSION (P.794) Regulator board software version
Table 7.5 – WebPak 3000 Register Map, Drop_1: Master Write Registers, BASIC and FULL Connections. Control/Reference Data (Drive Input Data)
Register Bit Parameter Name (Number) Description Settings
32 Sequencing control word Word containing drive sequencing and control bits
0 Section run
1 Section off
2 Fault/alarm reset
3 Jog forward
4 Jog reverse
5 Underwind
6 Slack take up
7 Tension on
8Diameter reset
Control/reference data are read by the regulator every 10 msec.
Table 7.4 – WebPak 3000 Register Map, Drop_1: Master Read Registers, BASIC and FULL Connections. Tunable, Configurable, and Status Data (Drive Output Data) (Continued)
Register Bit Parameter Name (Number) Description Settings
Tunable, configurable, and status data are updated by the regulator approximately every 600 msec.