43 Reserved
44
ANLG MAN REF GAIN ADJ (P.104) Scales the analog manual reference gain gain * 1000
45
ANLG MAN REF ZERO ADJ (P.105) Offset removed from the analog manual reference signal
46
TRIM REFERENCE SELECT (P.108) Trim reference selection 0=REGISTER; 1=ANALOG MANUAL;
2=
ANALOG IN 1; 3=NETW IN REG 1;
4=
NETW IN REG 2; 5=NETW IN REG 3;
6=
ANALOG IN 2
47
TRIM MODE SELECT (P.110) Type of trim mode selected
0=
NO
TRIM
; 1=
INCREMENTAL
; 2=
PROPORTIONAL
48 AUTO MODE MIN BYPASS (P.111) Disables minimum speed limit while in auto mode 0=OFF; 1=ON (min speed bypassed)
49
AUTO MODE RAMP BYPASS (P.112) Bypasses speed loop S-curve block while drive is in auto 0=OFF; 1=ON (rate limit bypassed)
50
STOP SPEED THRESHOLD (P.113) Speed threshold at which the main contactor will open
during a controlled stop
RPM
51 OCL PI PROP GAIN (P.808) OCL PI block proportional gain gain * 100
52
OCL PI LEAD FREQ (P.809) Outer control loop PI block lead break frequency radians/second * 100
53
OCL PI POSITIVE LIMIT (P.810) OCL PI block positive limit %
54
OCL PI NEGATIVE LIMIT (P.811) Outer control loop PI block negative limit %
55
OCL TRIM RANGE (P.812) Trim range for the OCL % * 10
Table 5.10 – FlexPak 3000 Original Register Map, Drop_2: Master Write Registers, FULL Connection. Configurable Data (Drive Input Data)
Register Bit Parameter Name (Number) Description Settings
56 INERTIA COMP SELECT (P.221) Source of inertia compensation 0=NONE; 1=INTERNAL; 2=ANALOG IN 1;
3=
ANALOG IN 2; 4=NETW IN REG 1 (P.905);
5=
NETW IN REG 2 (P.906); 6=NETW IN
REG 3 (P.907)
57
POS CURRENT LIM SEL (P.223) Selects positive current limit source 0=REGISTER ; 1=ANALOG IN 1; 2 = ANALOG
IN 2; 3=NETW IN REG; 4=NETW IN REG 2;
5=
NETW IN REG 3
58
NEG CURRENT LIM SEL (P.224) Selects negative current limit source
59
OCL REFERENCE SELECT (P.800) Selects OCL reference source 0=REGISTER; 1=ANALOG IN 1; 2 = ANALOG
IN; 3=FREQUENCY IN; 4=NETW IN REG 1;
5=
NETW IN REG 2; 6=NETW IN REG 3
Configurable data are read by the regulator approximately every 600 msec when Tune/Config Input Enable bit=1 and the drive is not running or jogging.
Table 5.9 – FlexPak 3000 Original Register Map, Drop_2: Master Write Registers, FULL Connection. Tunable Data (Drive Input Data) (Continued)
Register Bit Parameter Name (Number) Description Settings
Tunable data are updated by the regulator approximately every 600 msec when Tune/Config Input Enable bit = 1.