Owner manual

REPLACEMENT PARTS and ACCESSORIES
FlexPak 3000 49’1340 e
8-12
Radio Frequency Interference Filter
a) FlexPak 3000 converters with AC line input currents below 100 A:
If the RFI filter is connected, the HF emission limits for class A, group 1 (EN 55011) according to the
product standard EN 61800-3 are met and the drive is CE conform. This applies for the
1
st
environment (residential) as well as for the 2
nd
environment (industrial supply network).
b) FlexPak 3000 converters with AC line input currents above 100 A:
If the RFI filter is connected, the HF emission limits of class A, group 1 (EN 55011) in the 2
nd
environment (industrial supply network) are met, as required in the past for the Generic Standard
EN 50081-2. This is recommended if e.g. in industrial estates high power converters and offices with
sensitive consumers are connected to the same supply transformer.
The filter must be connected into the three AC line input phases L1 - L3 of the FlexPak 3000 in front of
the AC line reactor, as shown in figure H-1.
RFI Filter Selection
The RFI-Filters can be selected from Tab. 8-10 according to the permitted filter current and the
maximum operating voltage.
The permitted filter current is dependent on the application specific maximum continuous DC-current I
ad
of the drive, the DC-current form factor (FF) and the ambient temperature T.
The ambient temperature T is the max. temperature around the filter (typical 50°C inside cabinets for a
standard max. cooling air temperature of 40°C). Typical DC-current form factor FF = 1.05
For cabinet mounting with T = 50°C and FF = 1.05:
Filter current = maximum continuous DC-current I
ad
For other ambient temperatures (T) and form factors (FF) the continuous current of the filter can be
calculated as follows:
II
C
CT
FF I
C
CT
FILTER Line rms ad
°
°−
××
°
°−
()
45
85
2
3
45
85
Table 8-10:
RFI Filter Selection
RFI-Filter
Filter
380 - 440 V 460 - 500 V 690 V
Current
Part No. see Page Part No. see Page Part No. see Page
Application
25A 839.72.05 8-13 on request
36A 839.72.06 8-13 on request
50A 839.72.07 8-13 on request
80A 839.72.09 8-14 on request
100A 839.71.53 8-15 839.71.53 8-15
according
to a)
150A 839.70.20 8-16
180A 839.74.22 8-17 on request
250A 839.73.25 8-20 on request
270A 839.70.66 8-18 839.70.66 8-18
280A 839.72.67 8-17 839.72.67 8-17
340A 839.71.68 8-19 839.71.68 8-19
500A 839.73.31 8-20 on request
600A -
-
839.73.92
8-21
839.73.92
8-21
1000A 839.73.35 8-21 839.73.95 8-21 839.73.95 8-21
1600A 839.73.38 8-20 839.73.98 8-21 839.73.98 8-21
according
to b)