Owner manual

APPENDIX G
49’1340 e FlexPak 3000 G-7
Table G.1 - User Quick Reference Table for Input Parameters (continued)
Par.
Parameter Parameter Selection / Pg Initial Factory User Data
No.
Adjustment Range B- Setting Date Setting
Level Detectors
602 LEVEL DETECT 1 SELECT
SPD SOURCE SELECT OUT
SPEED RAMP INPUT TP
SPEED RAMP OUTPUT
SPD LOOP FEEDBACK
CML FEEDBACK
24 SPD LOOP
FEEDBACK
603 LEVEL DETECT 1 THRESH
0.1 to 100.0% if LEVEL
DETECT 1 SELECT is not set
to CML FEEDBACK
0.1 to MAXIMUM CURRENT%
if LEVEL DETECT 1 SELECT
is set to CML FEEDBACK
24 10.0%
604 LEVEL DETECT 1 DELAY 0.0 - 300.0 sec 24 10.0 sec
605 LEVEL DETECT 2 SELECT
SPD SOURCE SELECT OUT
SPEED RAMP INPUT TP
SPEED RAMP OUTPUT
SPD LOOP FEEDBACK
CML FEEDBACK
25 SPEED RAMP
INPUT TP
606 LEVEL DETECT 2 THRESH
0.1 - 100.0% if LEVEL
DETECT 2 SELECT is not set
to CML FEEDBACK
0.1 to MAXIMUM CURRENT%
if LEVEL DETECT 2 SELECT
is set to CML FEEDBACK
25 10.0%
607 LEVEL DETECT 2 DELAY 0.0 - 300.0 sec 24 10.0 sec
608 TACH LOSS SCR ANGLE 0 to 127 (degrees) 50 109
609 PHASE LOSS DETECT EN DISABLE, ENABLE 42 ENABLE
Outer Current Loop
800 OCL REFERENCE SELECT
REGISTER
ANALOG IN 1
ANALOG IN 2
FREQUENCY IN
NETW IN REG 1
NETW IN REG 2
NETW IN REG 3
40 REGISTER
801 OCL REF REGISTER -4095 - 4095 40 0
802 OCL REF RAMP TIME 0.0 - 300.0 sec 39 10.0 sec
803 OCL REF ROUNDING 0 - 50% 40 0%
804 OCL FEEDBACK SELECT
NONE
CML FEEDBACK
ANALOG IN 1
ANALOG IN 2
5=SPEED LOOP OUTPUT
6=ANALOG AUTO REF
7= NETW IN REG 1 (4.1 only)
8= NETW IN REG 2 (4.1 only)
9= NETW IN REG 3 (4.1 only)
37 CML
FEEDBACK
805
OCL LEADLAG SELECT
LEAD/LAG
BYPASS
LAG/LEAD
38 BYPASS
806 OCL LEADLAG LOW FREQ 0.01 - 34.90 rad/s 37 1.00 rad/s
807 OCL LEADLAG RATIO 2 - 20 37 10