User guide
C-12
FlexPak 3000 DC Drive Software Reference
OCL
TYPE
3
POSN
REG
EN
(P.814) •
DISABLED
•
ENABLED
DISABLED
OPEN
SCR
SENSITIVITY
(P.600) 0 to 100% 50%
OPEN
SCR
TRIP
THRESH
(P.601) 800 to 4000 1600
PHASE
FIRE
TEST
DELTA
(P.309) 0 to 180
DEGREE
0
DEGREE
PHASE
FIRE
TST
BRIDGE
(P.310) •
OFF
•
ON
OFF
PHASE
LOSS
DETECT
EN
(P.609) •
DISABLE
•
ENABLE
ENABLE
PLL
MAXIMUM
ERROR
(P.308) 2 to 1000 µsec 2 µsec
POS
CURRENT
LIM
SEL
(P.223) •
REGISTER
•
ANALOG
IN
1
•
ANALOG
IN
2
•
NETW
IN
REG
1
•
NETW
IN
REG
2
•
NETW
IN
REG
3
REGISTER
POSITIVE
CURRENT
LIM
(P.005) 0 to
MAXIMUM
CURRENT
(%
FLA
) 150 %
FLA
PRESET
SPEED
1 (P.117)
MINIMUM
SPEED
to
MAXIMUM
SPEED
(
RPM
or user-defined units)
250
RPM
PRESET
SPEED
2 (P.118)
MINIMUM
SPEED
to
MAXIMUM
SPEED
(
RPM
or user-defined units)
250
RPM
PRESET
SPEED
3 (P.119)
MINIMUM
SPEED
to
MAXIMUM
SPEED
(
RPM
or user-defined units)
250
RPM
PULSE
TACH
PPR
(P.207) 18 to 2500
PPR
18
PPR
PULSE
TACH
QUADRATURE
(P.208) •
ON
•
OFF
ON
RAMP
STOP
DECEL
TIME
(P.018) 0.1 to 300.0 seconds 5.0 seconds
REVERSE
DISABLE
(P.015) •
OFF
•
ON
OFF
S
-
CURVE
ROUNDING
(P.014) 0 to 50% 0%
SELF
TUNE
BRIDGE
(P.220) •
FORWARD
•
REVERSE
FORWARD
SELF
TUNE
FIELD
RANGE
(P.218) 0.90 to 5.00 1.00
Table C.1 – Parameter Settings Quick Reference Table (Continued)
Parameter
Parameter Selection/
Adjustment Range
Initial Factory
Setting (Default)
Your Data
Date Setting