User guide

13-6
FlexPak 3000 DC Drive Software Reference
F00060
SELF
TUNING
FAULT
Self tune aborted by external input.
Possible causes:
Operator stop asserted.
Drive interlock(s) open.
Drive fault became active.
F00061
SELF
TUNING
FAULT
Non-zero speed feedback at self-tune start.
Possible causes:
Analog tachometer only:
ANALOG
TACH
ZERO
ADJ
(P.202) not set properly.
Incorrect speed feedback scaling or offset.
Overhauling load causing motor shaft rotation.
F00062
SELF
TUNING
FAULT
Calculated armature inductance is out of range.
Possible causes:
Motor armature winding not connected or open circuit.
Blown inverting fault (DC) fuse.
Inverting fault breaker tripped.
Armature inductance too high. Tune current minor loop manually.
F00063
SELF
TUNING
FAULT
Maximum current with minimum rotation.
Possible causes:
Motor cannot rotate freely.
Motor load is too high.
Motor field not at normal operating temperature.
F00064
SELF
TUNING
FAULT
Attached inertia is out of range.
Possible causes:
Maximum self-tune speed reached.
Overhauling load present.
High mechanical friction present.
The speed loop cannot be self-tuned. Tune speed loop manually.
Table 13.1 – Fault Codes (Continued)
Code OIM Display Description