Table C.1 lists the recommended parts that must be provided by the user and can be
mounted separately at the time of installation. These recommended parts or an
equivalent are necessary for the proper operation and functionality of the Integrator
drive. Section 2.5, General Wiring Practices, details how to electrically connect these
recommended parts for proper drive operation.
Table C.1 – Recommended Parts
Part Description Qty Reliance Part Number Rating
AC Line Fuse (1FU, 2FU, 3FU)
1
:
1.5 thru 5 HP @ 230 VAC/3 thru 10 HP @ 460 VAC 3 64676-120AMX 40A, 500V
7.5 thru 10 HP @ 230 VAC/15 thru 20 HP @ 460 VAC 3 64676-120ARX 80A, 500V
15 HP @ 230 VAC/30 HP @ 460 VAC 3 64676-120ASX 90A, 500V
20 thru 30 HP @ 230 VAC/40 thru 60 HP @ 460 VAC 3 64676-120AVX 150A,500V
75 HP @ 230 VAC/150 HP @ 460 VAC 3 64676-120BAX 350A, 500V
Field Fuse (6FU, 7FU, 8FU):
1.5 thru 30 HP @ 230 VAC/3 thru 60 HP @ 460 VAC 3 64676-30K 15A, 600V
75 HP @ 230 VAC/150 HP @ 460 VAC 3 64676-30M 25A, 500V
“FN” Contactor:
1.5 thru 2 HP @ 230 VAC/3 thru 4 HP @ 460 VAC 1
705310-60A or 100-A12ND3
2
600V, 22A
3 thru 5 HP @ 230 VAC/6 thru 10 HP @ 460 VAC 1 705310-60A or 100-A12ND3 600V, 22A
7.5 thru 10 HP @ 230 VAC/15 thru 20 HP @ 460 VAC 1 705310-63A or 100-A24ND3 600V, 35A
15 thru 20 HP @ 230 VAC/30 thru 40 HP @ 460 VAC 1 705310-65A or 100-A45ND3 600V, 80A
25 HP @ 230 VAC/50 HP @ 460 VAC 1 705310-65Aor 100-A45ND3 600V, 80A
30 HP @ 230 VAC/60 HP @ 460 VAC 1 705310-66Aor 100-A75ND3 600V, 100A
75 HP @ 230 VAC/150 HP @ 460 VAC 1 705310-70Aor 100-B180ND3 600V, 225A
AC Line Disconnect
3
:
1.5 thru 25 HP @ 230 VAC/3 thru 50 HP @ 460 VAC 1 65242-100NSX 600V, 100A
30 HP @ 230 VAC/60 HP @ 460 VAC 1 65242-100SSX 600V, 150A
75 HP @ 230 VAC/150 HP @ 460 VAC 1 65242-300FSX 600V, 400A