Drive Setup and Adjustment
3-5
3.4.1 Set the Regulator Type (Jumper J15)
J15 determines whether the drive uses speed/voltage or torque/current regulation.
When
CURRENT is selected, only the terminal strip, the DeviceNet Communication
Board, or the AutoMax Network Communication Board can be used as a control
source. When J15 is set to
CURRENT, the drive is fixed in auto mode and cannot be
changed.
Also note that speed/voltage parameters must be set to provide overspeed protection
for the drive.
Table 3.1 – Jumper Settings
JUMPER
DEFAULT
SETTING FINAL SETTING
J15 (REGULATOR TYPE) SPEED
J16 (OIM PROGRAM) ENABLE
J20 (FIELD LOSS DETECT) ENABLE
J21 (FIELD SUPPLY JUMPER) B-C
J19 (MANUAL REF) POT
J14 (TACH V RANGE) 62
J11 (TACH V SCALE) 16
J10 (AUTO REF) VOLTS
J12 (AUTO REF) VOLTS
J18 (ARM I FB RB) Position 4
J26 (not used)
Jxx is not used. Do not
install a shorting bar
across pins of this jumper.
J27 (SPARE 1) (not used)
J28 (FILTER SELECT) (not used)
J29 (SPARE 2) (not used)
J30 (POWER UNIT) LOW