User guide
Register Map for WebPak 3000 Drives
8-21
N11:77 POSITION VERNIER P.241 Output of the position major loop
N11:78
POS LL WLO OUT P.246 Value of the position loop lead/lag low frequency
N11:79
POS LL RATIO OUT P.247 Value of the position loop lead/lag ratio
N11:80
POS PI KP OUT P.248 Value of the position loop PI proportional gain
N11:81
POS PI WLD OUT P.249 Value of the position loop PI lead frequency
N11:82
POS LOOP ERROR P.254 The difference between POSITION REFERENCE (P.240)
and position feedback
N11:83
TEN/DANCER FDBK SCALED P.489 Output of the tension/dancer feedback scaling block
N11:84
TENSION ON DIN TP P.498 0 = OFF, 1 = ON
N11:85 TENSION COMMAND P.850 0 = OFF, 1 = ON
N11:86 STALL TENSION COMMAND P.899 0 = OFF, 1 = ON
N11:87 TEN TO CURRENT OUT P.876 Output of the tension loop’s tension-to-current scaling
block
N11:88
TEN PI KP OUT P.879 Value of the tension loop PI proportional gain
N11:89
TENSION VERNIER P.856 Output of the tension major loop in counts
N11:90
TAPER PERCENT P.859 Percent reduction to be applied to the tension
reference from the taper function
N11:91
TEN LOOP ERROR P.834 Difference between the tension ramp output and the
tension/current loop feedback signal
N11:92
TEN RAMP OUTPUT P.842 Output of the tension major loop ramp block after
tension-to-current conversion
N11:93
TENSION DEMAND P.844 Output of the tension setpoint generator in counts
N11:94
ROLL DIAMETER P.865 Value of the calculated roll diameter in engineering
units
N11:95
NORM ROLL DIAMETER P.131 Value of the roll diameter normalized at 1.000 at
EMPTY CORE DIAMETER (P.830)
N11:96
DIAMETER CALC OUTPUT P.132 Value of the calculated roll diameter normalized at
1.000 at
EMPTY CORE DIAMETER (P.830)
N11:97
DIAMETER ANALOG P.821 Output of the diameter calculator scaled from zero at
empty core to 4095 at full roll diameter
N11:98
DIAMETER/TAPER IN TP P.192 Value of the diameter/taper range input in counts after
gain and zero have been applied
N11:99
UNWIND DIAMETER IN P.828 Analog signal of diameter/taper analog input when
DIAMETER/TAPER SELECT (P.870) is set to diameter.
N11:100
DIAMETER SELECT A TP P.495 0 = OFF, 1 = ON
N11:101 DIAMETER SELECT B TP P.496 0 = OFF, 1 = ON
N11:102 DIAMETER RESET TP P.829 0 = OFF, 1 = ON
N11:103 DIAMETER RST DIN TP P.497 0 = OFF, 1 = ON
N11:104 NETW COMM STATUS P.908 0 = NOT ACTIVE, 1 = ACTIVE
Table 8.2 – File N11:x (Drive Display Data (Read Only)) for WebPak 3000 Drives (Continued)
File
Address Parameter Name
Parameter
Number Description