User guide

Register Map for WebPak 3000 Drives
8-7
N10:167 NEG CURRENT LIM SEL P.224 Config 0 = REGISTER
1 = PARALLEL OCL
2 = NETW IN REG 1
3 =
NETW IN REG 2
4 =
NETW IN REG 3
N10:168
NEG CUR LIM INV EN P.226 Config 0 = DISABLED, 1 = ENABLED
N10:169 INV FAULT AVOID SEL P.312 Config 0 = DISABLED
1 = FAULT IMMEDIATELY
2 = DELAY BEFORE FAULT
N10:170 FEEDBACK SELECT P.200 Config 0 = ARMATURE VOLT
1 = DC TACH
2 = ENCODER
N10:171 ANLG TACH VOLTS/1000 P.203 Config 1 = 0.1 volts/1000 RPM
N10:172 ENCODER PPR P.207 Config 1 = 1 PPR
N10:173 SPEED PROFILER ENABLE P.127 Config 0 = DISABLE, 1 = ENABLE
N10:174 CURRENT MEMORY ENABLE P.314 Config 0 = DISABLE, 1 = ENABLE
N10:175 EMPTY CORE DIAMETER P.830 Config 1 = 0.01 IN
N10:176 FULL ROLL DIAMETER P.125 Config 1 = 0.01 IN
N10:177 DIAMETER CALC ENABLE P.826 Config 0 = DISABLE, 1 = ENABLE
N10:178 OCL SELECT P.817 Config 0 = NONE
1 = TENSION
2 = CURRENT
3 = POSITION
N10:179 OCL TYPE P.818 Config 0 = CASCADE, 1 = PARALLEL
N10:180 OCL TYPE 3 POSN REG EN P.814 Config 0 = DISABLED, 1 = ENABLED
N10:181 POS PROFILER ENABLE P.253 Config 0 = DISABLE, 1 = ENABLE
N10:182 POS LEADLAD BYPASS P.255 Config 0 = OFF, 1 = ON
N10:183 TAPER SET SELECT P.862 Config 0 = REGISTER, 1 = ANALOG
N10:184 TAPER TYPE P.863 Config 0 = LINEAR
1 = HYPERBOLIC
2 = TAPER REGISTER
N10:185 TEN PROFILER ENABLE P.878 Config 0 = DISABLE, 1 = ENABLE
N10:186 MOTOR HOT FLD AMPS P.510 Config 1 = 0.01 amps
N10:187
FIELD REF SELECT P.521 Config 0 = REGISTER
1 = FULL FIELD
2 = FIELD SHAPING
N10:188 FIELD DELTA HIGH LIM P.587 Config 1 = 1 degree
N10:189
FIELD LOSS THRESHOLD P.512 Config 1 = 1% of MOTOR HOT FLD AMPS
N10:190 FIELD AUTO WEAKEN P.517 Config 0 = DISABLED, 1 = ENABLED
N10:191 FULL FIELD DIAMETER P.124 Config 1 = 0.01 in
N10:192
WEAKENED FIELD DIA P.126 Config 1 = 0.01 in
N10:193
MOTOR SPD AT MAX FLD P.540 Config 1 = 1 RPM
Table 8.1 – File N10:x (Drive Read/Write Parameters) for WebPak 3000 Drives (Continued)
File
Address Parameter Name
Parameter
Number Type Scale