User guide
7-10
ControlNet Network Communication Option Board For Use With FlexPak 3000 and WebPak 3000 DC Drives
N10:195 FREQ OUT SELECT P.425 Config 0 = CML FEEDBACK
1 =
CML REFERENCE
2 = CML ERROR
3 =
SPD LOOP FEEDBACK
4 = SPD LOOP REFERENCE
5 =
SPD LOOP ERROR
6 = SPD LOOP OUTPUT
7 =
SPEED RAMP OUTPUT
8 = SPEED RAMP INPUT TP
9 =
SPD SOURCE SELECT OUT
10 = TRIM OUTPUT
11 =
ARMATURE VOLTAGE
12 =
ANALOG TACH FEEDBACK
13 =
PULSE TACH FEEDBACK
14 =
ZERO
15 =
FULL SCALE
16 = POWER OUTPUT
17 =
OCL REFERENCE
18 = OCL RAMP OUTPUT
19 =
OCL FEEDBACK
20 = OCL OUTPUT
21 =
FIELD REFERENCE
22 = FIELD FEEDBACK
23 =
NETW IN REG 1
24 =
NETW IN REG 2
25 =
NETW IN REG 3
N10:196
FREQ OUT ZERO P.426 Config 1 = 1 kHz
N10:197
FREQ OUT FULL SCALE P.427 Config 1 = 1 kHz
N10:198
DIG IN 0 SELECT P.428 Config 0 = BRUSH WEAR INPUT
1 =
JOG SPEED SELECT
2 = OCL ENABLE
N10:199 LEVEL DETECT 1 SELECT P.602 Config 0 = CML FEEDBACK
1 =
SPD LOOP FEEDBACK
2 = SPD RAMP OUTPUT
3 =
SPD RAMP INPUT TP
4 = SPD SOURCE SELECT OUT
N10:200 LEVEL DETECT 2 SELECT P.605 Config 0 = CML FEEDBACK
1 =
SPD LOOP FEEDBACK
2 = SPD RAMP OUTPUT
3 =
SPD RAMP INPUT TP
4 = SPD SOURCE SELECT OUT
N10:201 Spd Loop Pi Init Sel --- Config 0 = ZERO
1 =
SPD LOOP PI INIT VAL
2 = ANALOG MAN TRIM REF
N10:202
|
N10:273
Reserved --- --- Reserved (future parameter expansion)
Table 7.1 – File N10:x (Drive Read/Write Parameters) for FlexPak 3000 Drives (Continued)
File
Address Parameter Name
Parameter
Number Type Scale