User guide
7-6
ControlNet Network Communication Option Board For Use With FlexPak 3000 and WebPak 3000 DC Drives
N10:99
|
N10:149
RESERVED --- --- Reserved (future parameter expansion)
N10:150
CONTROL SOURCE SELECT P.000 Config 0 = TERMBLK
1 =
KEYPAD
2 =
SERIAL
3 =
NETWORK
N10:151 CNI PROG/RUN MODE P.915 Config 0 = STOP
1 = USE LAST REF
2 = USE TRMBLK CNTL
N10:152 MOTOR RATED ARM AMPS P.008 Config 1 = 0.1 amp
N10:153
MOTOR RATED ARM VOLTS P.009 Config 1 = 1 volt
N10:154
MAXIMUM CURRENT P.007 Config 1 = 1% of MOTOR RATED ARM AMPS (P.008)
N10:155
CML REF LIMIT SELECT P.311 Config 0 = SPD LOOP PI LIMITS, 1 = REGISTER
N10:156 TOP SPEED P.011 Config 1 = 1 RPM
N10:157 REVERSE DISABLE P.015 Config 0 = OFF, 1 = ON
N10:158 MANUAL REF SELECT P.106 Config 0 = ANALOG, 1 = MOP
N10:159 AUTO REFERENCE SELECT P.103 Config 0 = ANALOG, 1 = FREQUENCY IN
N10:160 INERTIA COMP SELECT P.221 Config 0 = NONE
1 =
INTERNAL
2 = ANALOG IN 1
3 =
ANALOG IN 2
4 =
NETW IN REG 1
5 =
NETW IN REG 2
6 =
NETW IN REG 3
N10:161
POS CURRENT LIM SELECT P.223 Config 0 = REGISTER
1 = ANALOG IN 1
2 =
ANALOG IN 2
3 =
NETW IN REG 1
4 =
NETW IN REG 2
5 =
NETW IN REG 3
N10:162
NEG CURRENT LIM SELECT P.224 Config 0 = REGISTER
1 =
ANALOG IN 1
2 =
ANALOG IN 2
3 =
NETW IN REG 1
4 =
NETW IN REG 2
5 =
NETW IN REG 3
N10:163
NEG CUR LIM INV EN P.226 Config 0 = DISABLED, 1 = ENABLED
N10:164 INV FAULT AVOID SEL P.312 Config 0 = DISABLE
1 =
FAULT IMMEDIATELY
2 = DELAY BEFORE FAULT
N10:165 FEEDBACK SELECT P.200 Config 0 = ARMATURE VOLT
1 =
DC TACH
2 = PULSE TACH
3 =
AC TACH
Table 7.1 – File N10:x (Drive Read/Write Parameters) for FlexPak 3000 Drives (Continued)
File
Address Parameter Name
Parameter
Number Type Scale