Configuration Guide User guide
Chapter 6 Configuring FactoryTalk Historian
82 Rockwell Automation Publication HSE-IN024A-EN-E–December 2012
2. Calculate the number of licenses for the Rockwell license
pool.
Take the number of your FHLD licenses, FHSE licenses, and
the <BaseLicenseCount> value, and then substitute them into
the following equation:
<RockwellLicensePool> = ∑ <FHLD licenses> + ∑ <FHSE
licenses> - <BaseLicenseCount>
3. Calculate the number of licenses for the General license pool.
Take the number of your PTY3 licenses, the FHSE3ADD
licenses, and the <BaseLicenseCount> value, and then
substitute them into the following equation:
<GeneralLicensePool> = ∑ <PTY3 licenses> +
<BaseLicenseCount> + ∑ <FHSE3ADD licenses>
In the following example we will calculate how licenses will be
distributed between the General and Rockwell license pools with
FHSE3ADD license activations.
We will use the following values:
Activation Value ∑
FHSE.2K 2000 12000
FHSE.10K 10000
FHSE3ADD.2K 0 2000
FHLD.5K 5000 5000
PTY3.500 500 500
Total
19500
To distribute licenses between the license pools:
1. Calculate the <BaseLicenseCount> value.
<BaseLicenseCount> = 20% * ∑ <FHSE licenses>
<BaseLicenseCount> = 20% * 12000
Distributing Licenses with