Installation Guide 5.0 Owner manual

1 INTRODUCTION
9
• • • • •
(optional) SIMATIC NET if you want to connect to Siemens S7 processors via MPI
(Multi Point Interface) or PROFIBUS protocol
(optional) INAT H1 driver if you are using an H1 protocol with a Siemens S5
controller (The driver is available at
http://www.inat.de/index.php?18&backPID=18&tt_products_sof=226&L=1)
Network requirements
Your Microsoft Windows network must use the TCP/IP protocol.
If you use a firewall, you must configure the firewall to permit traffic on the following
ports:
Some of these ports may vary on your network. Work with your network administrators to
determine the correct port numbers to open.
You may need to open ports for other Rockwell Automation products as well. See
“Additional ports you may have to open” on page 82.
This port: is used for:
TCP port 25 SMTP mail
TCP port 80 Standard WWW port
TCP port 135 Remote Process Calls
TCP port 139 File and printer sharing
TCP port 445 File and printer sharing
TCP port 1433 Communications to SQL Server
TCP ports 7002 - 7004 FactoryTalk AssetCentre
UDP port 137 File and printer sharing
UDP port 138 File and printer sharing
UDP port 1434 Browsing for SQL Servers
UDP port 21060 Rockwell Automation Trace Diagnostics
UDP port 21061 Rockwell Automation Trace Diagnostics