Installation Instructions User guide

2 F-Series Motor Installation Instructions
Publication 1398-IN516B-EN-P — February 2002
Receiving and Maintenance Information
The customer is responsible for inspecting the equipment before
accepting the shipment from the freight company. Check the item(s) you
receive against your purchase order.
Maintain your motor within the following environmental conditions:
in a clean, dry location
within the operating temperature range, 0° to 40° C (32° to 104° F)
within the storage temperature range, -30° to 70° C (-25° to 158° F)
within the relative humidity range, 5% to 95% non-condensing
in a non-corrosive atmosphere
Motor Catalog Number Identification
FACTORY DESIGNATED OPTIONS
AA Standard Flange
AN NEMA (4000 Series Only)
OPTIONS
00 Standard
04 24V DC Brake
OPTICAL ENCODER LINE COUNT
F 1000
H
2000 (Standard)
K
5000
1
1
The 5000 line count encoder limits the motors top speed to 3600 RPM due to frequency output limit of the encoder.
Check drive system configuration data for additional restrictions imposed by drive input.
L 500
M 3000
MOTOR WINDING Ke DESIGNATOR
FRAME SIZE
SERIES DESIGNATOR
F Medium Inertia
F -4030-Q-H00 AA