t Owner manual

Rockwell Automation Publication IASIMP-QS016C-EN-P - October 2014 307
FactoryTalk View ME Energy Faceplates Chapter 11
Configure Studio 5000 Logix Designer Application for the Kinetix Drive Faceplate
Follow these procedures to configure the faceplate.
Add the Kinetix Drive to Your Ethernet Network
1. Create a new or open an existing Logix Designer application file.
2. Under I/O Configuration, right click the network communication module to be used for the intended drive.
3. Select ‘New Module’.
4. Select the applicable Kinetix drive and click Create.
5. Enter a distinct module name and the IP Address of your drive.
(For example, we use My5500 for the module name throughout this document.)
IMPORTANT
This step assumes you have already added and configured an Ethernet module to your I/O tree.