User Guide 1/4 - 2 HP, 115/230 VAC
18 Installation
Feedback Switch
Set to ARM for armature feedback,
or TACH for tachogenerator
feedback.
Armature Voltage Switch
Set to 90 for 90 VDC motor,
or 180 for 180 VDC motor.
Line Voltage Switches
Set to 115 for 115 VAC line voltage, or
230 for 230 VAC line voltage.
Figure 6. Slide Switch Locations
250-0285-rev1.qxd 4/26/00 9:36 AM Page 18