Installation
Cage-clamp terminal block
Connections to the DC3R drive are made to a cage-clamp terminal block
(Figure 4). To insert a wire into the terminal block, press down on the
lever arm using a small screwdriver. Insert stripped wire into the large
opening in front of the terminal block. Release the lever arm to clamp the
wire.
Lever Arm
Figure 4. Cage-Clamp Terminal Block
Field output
The field output is for shunt wound motors only. Do not make any
connections to F1 and F2 when using a permanent magnet motor.
Use 18 AWG wire to connect the field output to a shunt wound motor.
Table 1 lists the field output connections.
Table 1. Field Output Connections
Line Voltage Approximate Connect Motor
(VAC) Field Voltage (VDC) Field To
115 50 F1 and L1
115 100 F1 and F2
230 100 F1 and L1
230 200 F1 and F2